Please login to your account first. Continue using Ucbis.com!
Home > Shenzhen Chengtiantai Cable Industry Development Co.,Ltd> Domestic Use Flexible Electric Wire 318-Y / H05VV F Cable 5×0.75 Sq. Mm

Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

60227 IEC 01 (H07V-U / (H07V-R)),60227 IEC 02 (H07V-K)
  • Annual Revenue 350 million-500 million USD
  • Employees 250~300
  • Year Established 1983
  • Manufacturer, Exporter

Certification

See All
Copyright 2023 ucbis.com All Rights Reserved.

Domestic Use Flexible Electric Wire 318-Y / H05VV F Cable 5×0.75 Sq. Mm


 

PVC insulated multi-core cables with flexible conductor H05VV-F 5 x 0.75 mm²

 

Applications:

For household appliances working under humid and medium mechanical stress.

Installation:

  • In industries
  • In houses
  • Suitable for installation in electrical installation pipes or similar closed systems - surface or flush mount

 

  Quick details

 

 
Product category: H05VV-F
Austrian type: YMM
Number of cores: 5
Nominal cross section: 5 x 0.75 mm²
Overall diameter approx: 7.4 - 9.3 mm
Net weight approx: 95 kg / km
Standard delivery length: 100 m
Conductor DC resistant at 20°C: 26 Ohms / km
Current carrying capacity: 13 A

 

 

 

  Description

 

 

Standards/references:

  • International: IEC 60227
  • National: GB/T5023-2008

Color options:

red, yellow, blue, black, green, green/yellow (other colors can be supplied on request)

 

 

  Characteristics

  Construction characteristics

Conductor material Fine wire according to IEC 60228 class 5
Insulation polyvinyl chloride (PVC)
Outer Sheath polyvinyl chloride (PVC)

  Dimensional characteristics

Number of cores 5
Conductor cross-section 0.75 mm2
Outer diameter Ø min. - max. 7.4 - 9.3 mm
Approximate weight 95 kg / km

  Electrical characteristics

Rated voltage Uo/U (Um) 300 / 500 V
Maximum current rating air 25°C 13 A
Maximum DC resistance, conductor 20°C 26 Ω / km
Test voltage 2000 V

  Usage characteristics

Maximum operating temperature 70 °C
Short-circuit max conductor temperature(duration up to 5 S) 160 °C
Temperature range - 5 to + 70 °C

  Installation conditions

Installation temperature 5 °C
Minimum bending radius 4 x cable diameter
Recommended maximum tensile stress 50 N / mm²
Note:
  • Photographs are not to scale and do not represent detailed images of the respective products
  • Prices are net prices without VAT and surcharges
  • Sale to business customers only
  • Information in this document is subject to change without notice
Some great shots of our manufactering plant
 
Waterproof 5 Core Armoured Cable , Electrical Power Cable For Residental Connections Waterproof 5 Core Armoured Cable , Electrical Power Cable For Residental Connections Waterproof 5 Core Armoured Cable , Electrical Power Cable For Residental Connections
Mannufacturing plant R&D Building Bird's eye view of the plant
Waterproof 5 Core Armoured Cable , Electrical Power Cable For Residental Connections Waterproof 5 Core Armoured Cable , Electrical Power Cable For Residental Connections Waterproof 5 Core Armoured Cable , Electrical Power Cable For Residental Connections
MV Power Cable Workshop Cable Reels Waiting to be shipped out Shipping
 

 

Visit Website