Please login to your account first. Continue using Ucbis.com!
Home > Guangzhou Rongtao Medical Tech LTD.> S5-1 Sector Ultrasound Transducer cardiac Sector Probe Ultrasound

Guangzhou Rongtao Medical Tech LTD.

Top preferred ultrasonic board repair, experienced repair engineers team, ultrasound transducer probe & related medical spare parts for sale
Business License,EXPORT ENTERPRISE REGISTRATION
  • Annual Revenue 5,000,000-10,000,000 USD
  • Employees 50~60
  • Year Established 2014
  • Distributor/Wholesaler, Exporter, Trading Company, Seller

Certification

See All
Copyright 2023 ucbis.com All Rights Reserved.

S5-1 Sector Ultrasound Transducer cardiac Sector Probe Ultrasound


 

S5-1 Sector ultrasound transducer


1.Type: sector
2.Frequency: 5.0-1.0 MHz
3.Compatible system: EPIQ 5, Epiq 7,CX50
4.Application: adult, pediatric, cardiac
5.Condition: pre-owned and original, in good working condition
6.With 60 days warranty

 

 

 

 

 

 

 

Other Philps probes we can offer:

 

 

Brand Model Compatible System
(CX50/EPIQ/Affiniti) C5-1 CX50/EPIQ/Affiniti
(CX50/EPIQ/Affiniti) C8-5 CX50/EPIQ/Affiniti
(CX50/EPIQ/Affiniti) C10-3V CX50/EPIQ/Affiniti
(CX50/EPIQ/Affiniti) L12-3 CX50/EPIQ/Affiniti
(CX50/EPIQ/Affiniti) L12-5 CX50/EPIQ/Affiniti
(CX50/EPIQ/Affiniti) S5-1 CX50/EPIQ/Affiniti
(CX50/EPIQ/Affiniti) S8-3 CX50/EPIQ/Affiniti
(CX50/EPIQ/Affiniti) S12-4 CX50/EPIQ/Affiniti
(CX50/EPIQ/Affiniti) C6-2 CX50/Affiniti
(CX50/EPIQ/Affiniti) L12-5 CX50/EPIQ/Affiniti
(CX50/EPIQ/Affiniti) S5-1 CX50/EPIQ/Affiniti
ClearVue L12-4 ClearVue 350/ ClearVue 550/ClearVue 650/Affiniti 50/CX30
HD Series 3D9-3V HD11XE/HD15/iU22/EPIQ 5
HD Series S6-2mpt HD7 and EnVisor
HD Series C8-5 HD15/ HD11 XE/ HD11/ HD7/ EnVisor and HD9
Envisor L12-3 Envisor
HD Series C8-4V HD6/ HD7/ HD7XE/ HD9/ HD15/ HD11XE
HD Series C9-4 HD3/ HD11 and HD11 XE
HD Series L12-3 HD6/ HD7/ HD7XE/ HD11/ HD11XE / HD15
HD Series S4-2 HD11XE/ HD7/ EnVisor/ HD11 and HD9
HD Series S4-2 HD11XE/ HD7/ HD11 and HD9
HD Series S4-2 HD11XE/ HD7/ EnVisor/ HD11 and HD9
IU22 3D6-2 iU22/iE33
IU22 C6-3 iU22/iE33
IU22 C8-4V iU22/iE33
IU22 C8-5 iU22/iE33
IU22 C9-4 iU22/iE33
IU22 L9-3 iU22/iE33
IU22 L12-5 iU22/iE33
IU22 L15-7io iU22/iE33
IU22 S3-1 iU22/iE33
IU22 S4-1 iU22/iE33
IU22 V6-2 iU22/iE33
IU22 X3-1 iU22/iE33
IU22 X6-1 iU22/iE33
IU22 S5-1 iU22/iE33
IU22 S8-3 iU22/iE33
IU22 VL13-5 iU22/iE33
/ATL C7-4 ATL HDI 3000 /HDI 3500/HDI 4000/ HDI 5000
/ATL C9-5 HDI 1500/3000/3500/4000/5000
/ATL L7-4 UM9 /HDI 1500/ HDI-3000/HDI 3500/HDI 5000
/ATL MPT7-4 HDI 5000
/ATL P7-4 UM9 /HDI 1500/ HDI-3000/HDI 3500/HDI 5000
/HP C3540/21321A EnVisor/ Imagepoint and Sonos Series
/HP C5040/21373A SONOS 4500/5500/7500/ Image Point/ Image Point HX/ and EnVisor
/HP E6514/21370A Imagepoint
/HP L7535/21359A Envisor/ Envisor HD/ Image Point/ Image Point HX
/HP S8 & HP Sonos 4500/ Sonos 5500/ Sonos 7500/ EnVisor and HD7XE
/HP S3 HP Sonos 4500/ 5500 and 7500
/HP S4 Sonos 4500 & 5500
/HP P7510/21375A Imagepoint /Sonos 1800
/HP X4 HP Sonos 7500
/HP 11-3L / HP Sonos 4500/ Sonos 5500/ Sonos 7500
/HP T6210 Sonos 5500/ Sonos 7500

 

 

 

 

Knowledge point

 

 

Benefits of Purewave when you practice

 

It typically takes longer to perform and ultrasound on a technically difficult to scan patient. Image optimization is more difficult, and the sonographers must work harder to create acceptable images. The sonographer may even have to try several different transducers before finding the one that provides adequate penetration yet yields images clear enough to perform a diagnosis.

Many of those problems and stressors are reduced or gone with the PureWave technology. Additionally, the technology makes the probes lighter, reducing the strain on sonographers who are scanning all day. Fewer probes, faster scans, clearer images. Period.

Visit Website